8.3.2 Tappet housing check
Use an internal dial gauge to measure the diameter of the tappet housings X. Use value of A detected (Par. 8.3.1) to calculate the clearance value (Tab. 8.4). If the clearance values are not observed, replace the worn component.
Important
- Tab. 8.4 details the dimensional values of new components only.
Tab. 8.4 Tappets and tappet housing size.
REF. |
DIMENSIONS (mm) |
CLEARANCE VALUE (mm) |
A |
11.966 - 11.984 |
0.060 - 0.105
|
X |
12.000 - 12.018 |
B |
46.5 ± 0.2 |
--- |
|