11.8.1 Information
Hydraulic pumps on the 3rd and 4th PTO can be installed at the same time. In some configurations, there is also the centering ring C on the 4th PTO.
Important
- For disassembly or installation, refer to Par. 11.5, Par. 11.6 e Par. 11.7.
- Always replace the gasket of the rings B and C and flanges D and K at each assembly.
- Lubricate the gear H with oil.
|
Fig. 11.46
|