The check is carried out by exerting a slight deflection or bending along the pipe and near the hose clamps. Components must be replaced if they have clear signs of cracks, tears, cuts, leaks and do not retain a certain degree of elasticity.
Important
Before proceeding with operation, read Par. 3.2.2.
If hoses are damaged contact an authorized KOHLER workshop.
Fig 5.7
Loosen the capscrews E and remove guard F.
Check that the:
Fuel system hoses A are intact.
Hoses for the cooling circuit B1 and B2.To access the control of the cooling hoses B1 unscrew the four screws E and remove the safe guard F.
Vent system pipes C.
Air system ducts D.
When the control is finished the safe guard F mount and tighten the screws E.