4.3.1 Starting
- Check the level of the engine oil, fuel and coolant and fill if necessary (Par. 4.5 e Par. 4.6).
- Put the ignition key in the ignition switch.
- Tun the key to 1 position.
- Press the Start push button for it to start automatically.
Important
- RPM reading delay is normal.
- If engine does not start after two attempts see Tab. 7.1 and Tab. 7.2 to found the cause.
|

Fig. 4.1
|
4.3.2 After starting
Warning
- Make sure that all the warning lights on the control panel are off when the engine is running.
- Check for any leakages from the pipes on first start-up
AMBIENT TEMPERATURE |
TIME |
≤-20°C |
2 minutes |
from -20°C a -10°C |
1 minutes |
from -10°C a -5°C |
30 seconds |
from -5°C a 5°C |
20 seconds |
≥ 5°C |
15 seconds |
|
4.3.3 Turning off
- Do not turn off the engine with a full load or when it is running at the maximum rotation speed. Leave it running at idle speed without a load for approximately 1 minute.