IMPORTANT ! Stop the engine and let it cool before you start work. Do not start the engine during the service procedures.
|
1 |
Check if other fault codes detected are found:
- Yes: Refer also to the other fault codes before going to step 2
- NO: Proceed to Step 2
|
2 |
Erase the fault code with the Kohler Diagnostic Tool and restart the engine. If the fault code are still present proceed with the step 3.
|
3 |
With the Kohler Diagnostic Tool check the Injector Electrical Dynamic Test.
|
4 |
Check for any debris or water inside the connector terminals. This may be as a consequence of pressure washing the engine, loose connectors or poor connector sealing.
|
5 |
Check the harness engine and machine, is not damaged and is routed correctly (to the machine harness refere to the machine workshop manual).
|
6 |
If the problem is not solved replace the Engine Electronic Control Unit ECU
|