P0615

Starter Switch short to battery.

 

This fault code indicates the ECU has detected a fault on the Starter Motor Switch.

 

Service Procedures:

IMPORTANT !
Stop the engine and let it cool before you start work.
Do not start the engine during the service procedures.

1

Check if other fault codes detected are found:

  • Yes: Refer also to the other fault codes before going to step 2
  • NO: Proceed to Step 2
2

Check for any debris or water inside the connector terminals.
This may be as a consequence of pressure washing the engine, loose connectors or poor connector sealing.

3

Check the harness engine and machine, is not damaged and is routed correctly (to the machine harness refere to the machine workshop manual).

4

Complete the testing procedure described in the help page Engine Starter Switch

 

FTB - Related Faults:

15 Circuit Short To Battery or Open

 