Search

First start procedure

Fuel system filling

 

  Important

  • Follow this instruction at the first start of the engine or in case the engine has stopped for empty fuel tank.
  1. Fill the fuel tank with approved fuel in Par. 2.5.
 

For engine configuration with mechanical fuel feed pump

 

  1. Disconnect the connector A from injection pump and put the connector A in a proper container. 
  2. Push the lever C of the fuel feed pump D till the fuel spills from connector A.
  3. Connect the connector A on the injection pump B.

 

For engine configuration with electric fuel feed pump

 

  1. Disconnect the connector A from injection pump B and put the connector A in a proper container. 
  2. Turn the control panel key to ON position till the fuel spills from connector A.
  3. Turn the control panel key to OFF position.
  4. Connect the connector A on the injection pump B.
 

 

Wait Loading