Search

Exhaust Gas Recirculation (EGR) Valve

 

IMPORTANT !

 

Use the multi-meter on the harness connector pins.
DO NOT use the multi-meter on the ECU pins.

 

Step Fault description Action
1 Air inlet circuit fault
  • Check integrity of air inlet circuit:
  • Air filter secured and not blocked
  • Leaks on intake hoses:
  1. Intake to turbocharger hose
  2. Turbocharger to intercooler hose
  3. Intercooler to inlet manifold hose
  4. Inlet manifold/gasket secured
  5. EGR cooler closed
  • If no fault is found, proceed to Step 2.
2 EGR fault
  • Test to switch off and turn on the staring key
  • Check EGR Valve with the procedure described in the help page "EGR On/Off Valve Test.". Replace if necessary.
  •  If no fault is found, proceed to Step 3.
3 Wiring fault
  • Check the harness continuity, and machine and earth contacts.
  • Repair/replace as necessary
  • If fault persists, raise Kohler Service Helpdesk Call

 

 

 

Wait Loading